Application Areas:

For post-installed rebar connections with MCS Diamond and Uni Plus

Advantages:

  • For high tensile loads with low edge and spacing
  • Flexible embedment depth according to static requirements
  • Next line loads to the existing reinforcement in the component by means of an overlap joint for maximum load utilization
  • Metric thread stainless steel of the corrosion resistance class III, e.g. A4 from high corrosion resistant steel of the corrosion resistance class IV, e.g. Material 1.4529, for reliable use in outdoor and indoor
  • Problem solver, which is used when conventional heavy duty dowels are not sufficient
  • Design according to DIN 1045-1 (reinforcement theory) and ETAG 029 TR (anchor theory)
Threaded anchor  MULTICOMPOUNDsystem
Threaded anchor  MULTICOMPOUNDsystem

Advice

Maximum permissible load (see point 1) a single truss rod in normal concrete = (16/20) (2), with Bern MCS DIAMOND
In determining the overall approval Z-21.8-1944 is (3)
1) It regulated in DIN 1045-1 Partial safety factors of the resistances and a partial safety factor of YF = 1.4 are included
2) The authorization includes the use in concrete C 12/15 to C50 / 60
3) The same results are achieved when ETA 11/0077 is sized according to European Technical Approval
4) anchoring can be shortened according to static calculation
5) The minimum concrete cover according to DIN 1045-1 is observed. Values ​​can be smaller on a shortened BRA
6) Fracture of Steel authoritative