Product groups:

Application Areas:

To create wind and airtight layers for carpentry, roofing and interior finishing trade

Advantages:

  • Interior roof-side installation as a vapor barrier, airtight layer
  • Roof outer side laying in the restructuring case for well-shaped laying on the rafters, wind and air tightness layer under the rafters
  • Diffusible coating protects the supporting structure and insulation from moisture, structural moisture (e.g: from too moist built rafters) is removed from the construction
  • Moisture-regulating properties, controlled re-drying in summer, condensation prevention in winter, healthy and comfortable indoor climate
  • Easy to install and tear-resistant screening, overlap markings, translucent design, fiber mesh
  • Execution vapor barrier SK with mutual self-adhesive strips
  • Nail shaft longitudinal / transverse of 184/157 N / 5 cm
  • Sd value of 4 - 8 m

Processing information

The vapor barrier VB2 can be installed both lengthwise and crosswise to the substructure. When renovating from the outside, installation is carried out parallel to the eaves. The printed smooth side must face the processor. The overlap between the strips is at least 10 cm (see overlap marking). Lay the membrane without tension and fasten it at a maximum distance of 30 cm. Joints with sealing tape or diffusion band glue. Penetrations with air sealing sleeves or connection tape or diffusion tape seal.Glue to masonry and plaster levels using foil adhesive with a relief loop. Airtightness must be ensured for all indoor bonding. When laying in a trough as a renovation vapor barrier from the outside, an airspace-free connection on the side of the rafters must be ensured by gluing or using trellis battens. When used outdoors, tape joints with diffusion tape.

Advice

The printed smooth side must face the processor

Technical Data

Property Value
Length 50 m
Width 1.5 m
Surface Weight 110 g/m²
Fire behavior Euroclass E
Resistance to water penetration W1
Tensile strength along/across 105/120 N
Elongation along/across 50/40 %
Maximum tensile strength along/across 137/130 N
Material EVA-coated non-woven polypropylene
Color Transparent
Version Roll
Thickness 0.32 mm
Thermal stability (with predefined units) -40 °C - 80 °C
Weight 10.5 kg